Fluke 709H Precision Loop Calibrator w/ HART Communications/Diagnostics

Special Order - Harmon Details

Special Order - Washburn Details

Special Order - San Diego Details

Special Order - San Francisco Details

Special Order - Dallas Details

Details

INCLUDES:
• (1) Loop Calibrator
• (1) Extended Tooth Alligator Clip Set
• (1) 75X-8014 Stackable Lead Set
• (1) TP220 Test Probes
• (1) AC280 SureGrip Hook Clips
• (1) HART Cable
• (6) AAA Batteries
• (1) Soft Case
• (1) Product Manual CD-ROM
• (1) Quick Reference Guide

FEATURES:
• Adds a built-in HART modem that supports a select set of HART universal and common practice commands
• Read basic device information, perform diagnostic tests, and trim the mA output on most HART enabled transmitters
• Logging of HART data in the field
• Data log feature offers selectable capture with recording intervals of 1 to 60 seconds and a logging capacity of 9800 records or 99 individual sessions
• Store up to twenty HART device configuration files (with optional software)
• mA source, mA simulate, mA read, mA read/loop power, and volts read functions
• Best-in-class accuracy at 0.01% reading
• 24 VDC loop power with mA measure mode (-25% to 125%)
• Resolution of 1µA on mA ranges and 1mV on voltages ranges
• Built in selectable 250? resistor for HART communications
• Variable step and ramp time in seconds
• Valve test (source and simulate defined mA values with % keys
• Simple two wire connection for all measurements
• Auto shutdown to conserve battery life
• Intuitive user interface with quick-set knob for fast setup, easy use
• 128 x 64 pixels, graphic LCD with backlight, 0.34" high digits
• Compact rugged design with protective holster

SPECIFICATIONS:
• Functions: mA Source, mA Simulate, mA Read, mA Read/Loop Power, and Volts Read
• Ranges: mA (0 to 24mA) and Volts (0 to 30VDC)
• Resolution: 1 µA on mA Ranges and 1 mV on Voltage Range
• Accuracy: 0.01% +/- 2 Counts, All Ranges (@23° +/- 5°C)
• Operating Temperature Range: -10 to 55 °C (14 to 131°F)
• Humidity Range: 10 to 95% Non-Condensing
• Stability: 20 ppm of F.S. /°C from -10 to 18°C and 28 to 55°C
• Display: 128 x 64 Pixels, LCD Graphic w/Backlight, .34 High Digits
• Power: 6 AAA Alkaline
• Battery Life: 40 hours Typical
• Loop Compliance Voltage: 24VDC @ 20mA
• Over-Voltage Protection: 240 VAC
• Overload Current Protection: 28 mA DC


The Fluke 709H mA loop calibrator is designed to save time and produce high-quality results. The 709H offers HART communication and supports a select set of the HART universal and common practice commands. This makes the 709H unique as both an affordable,