SKU: Fluke 771
UPC: 095969349697
Weight: 0.85
Fluke 771 Milliamp Process Clamp Meter
Details
INCLUDES:
• (1) 771 Milliamp Process Clamp Meter
• (1) Soft Carrying Case
• (1) Quick Reference Guide
FEATURES:
• Measures 4 to 20 mA signals without breaking the loop
• Best in class 0.2% accuracy
• Delivers 0.01 mA resolution and sensitivity
• Measures mA signals for PLC and control system analog I/O
• Detachable clamp for measurements in tight locations
SPECIFICATIONS:
• Diameter of Measurable Conductor: 0.177" or 4.5 mm Max
• Operating Temperature: -10 to 50°C
• Storage Temperature: -25 to 60°C
• Operating Humidity: < 90% @ < 30°C, < 75% @ 30 to 55°C
• Operating Altitude: 0 to 2000 m
• IP Rating: IP 40
• Vibration: Random 2 g, 5 to 500 Hz
• Shock: 1 m Drop Test (Except the Jaw)
• EMI/RFI: Meets EN61326-1, for Current Measurement w/ JAW, Add 1 mA to Specification for EMC Field Strengths of 1 V/m up to 3 V/m
• Temperature Coefficient: 0.01% °C, (< 18°C or > 28°C)
• Power, Battery Life: (2) AA 1.5 V Alkaline, IEC LR6, 40 hours Typical
• mA Measurement (Measured by Clamp) Resolution / Range: 0 to 20.99 mA
• mA Measurement (Measured by Clamp) Accuracy: 0.2% + 2 Counts
• mA Measurement (Measured by Clamp) Resolution / Range: 21.0mA to 100.0 mA
• mA Measurement (Measured by Clamp) Accuracy: 1% + 5 Counts
Milliamp process clamp meters can measure mA signals without breaking the loop. The popular Fluke 771 mA Clamp Meter saves time by making fast, accurate measurements on 4-20 mA signal loops without breaking the circuit.
• (1) 771 Milliamp Process Clamp Meter
• (1) Soft Carrying Case
• (1) Quick Reference Guide
FEATURES:
• Measures 4 to 20 mA signals without breaking the loop
• Best in class 0.2% accuracy
• Delivers 0.01 mA resolution and sensitivity
• Measures mA signals for PLC and control system analog I/O
• Detachable clamp for measurements in tight locations
SPECIFICATIONS:
• Diameter of Measurable Conductor: 0.177" or 4.5 mm Max
• Operating Temperature: -10 to 50°C
• Storage Temperature: -25 to 60°C
• Operating Humidity: < 90% @ < 30°C, < 75% @ 30 to 55°C
• Operating Altitude: 0 to 2000 m
• IP Rating: IP 40
• Vibration: Random 2 g, 5 to 500 Hz
• Shock: 1 m Drop Test (Except the Jaw)
• EMI/RFI: Meets EN61326-1, for Current Measurement w/ JAW, Add 1 mA to Specification for EMC Field Strengths of 1 V/m up to 3 V/m
• Temperature Coefficient: 0.01% °C, (< 18°C or > 28°C)
• Power, Battery Life: (2) AA 1.5 V Alkaline, IEC LR6, 40 hours Typical
• mA Measurement (Measured by Clamp) Resolution / Range: 0 to 20.99 mA
• mA Measurement (Measured by Clamp) Accuracy: 0.2% + 2 Counts
• mA Measurement (Measured by Clamp) Resolution / Range: 21.0mA to 100.0 mA
• mA Measurement (Measured by Clamp) Accuracy: 1% + 5 Counts
Milliamp process clamp meters can measure mA signals without breaking the loop. The popular Fluke 771 mA Clamp Meter saves time by making fast, accurate measurements on 4-20 mA signal loops without breaking the circuit.